Siemens RUGGEDCOM i800
En bref
- Source
- NVD
- EPSS
- EPSS 1.07 % · centile 65 ()
- État
- PUBLISHED
- Publiée
- Mise à jour
- Attribuée par
- siemens
- Statut NVD
- Modified
Rechercher sur…
Description
After initial configuration, the Ruggedcom Discovery Protocol (RCDP) is still able to write to the device under certain conditions. This could allow an attacker located in the adjacent network of the targeted device to perform unauthorized administrative actions.
Faiblesses (CWE)
- CWE-1188 — Initialisation par défaut non sécurisée d'une ressource
- CWE-665 — Initialisation incorrecte
Références
Scores
| Version | Score | Vecteur | Évalué par |
|---|---|---|---|
| CVSS 3.1 | HIGH 8.8 | CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H | siemens |
| CVSS 3.1 | HIGH 8.8 | CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H | NVD · productcert@siemens.com (Secondary) |
| CVSS 3.0 | HIGH 8.8 | CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H | NVD · nvd@nist.gov (Secondary) |
| CVSS 2.0 | MEDIUM 5.8 | AV:A/AC:L/Au:N/C:P/I:P/A:P | NVD · nvd@nist.gov (Primary) |
Références européennes
- ENISA EUVD · EUVD-2017-4275
- GCVE · GCVE-0-2017-12736
Avis du CERT-FR
- CERTFR-2017-AVI-326 — Vulnérabilité dans SCADA Siemens Ruggedcom Discovery Protocol · cert.ssi.gouv.fr
Configurations affectées (CPE NVD)
cpe:2.3:o:siemens:scalance_xb-200_firmware:*:*:*:*:*:*:*:*≥ 3.0cpe:2.3:o:siemens:scalance_xc-200_firmware:*:*:*:*:*:*:*:*≥ 3.0cpe:2.3:o:siemens:scalance_xp-200_firmware:*:*:*:*:*:*:*:*≥ 3.0cpe:2.3:o:siemens:scalance_xr300-wg_firmware:*:*:*:*:*:*:*:*≥ 3.0cpe:2.3:o:siemens:scalance_xr-500_firmware:*:*:*:*:*:*:*:*≥ 6.1cpe:2.3:o:siemens:scalance_xm-400_firmware:*:*:*:*:*:*:*:*≥ 6.1cpe:2.3:o:siemens:ruggedcom_ros:*:*:*:*:*:*:*:*< 5.0.1cpe:2.3:o:siemens:ruggedcom_ros:*:*:*:*:*:*:*:*< 4.3.4
Produits affectés
| Produit | Versions |
|---|---|
| Siemens · RUGGEDCOM i800 | affected 0 < V4.3.4 |
| Siemens · RUGGEDCOM i800NC | affected 0 < V4.3.4 |
| Siemens · RUGGEDCOM i801 | affected 0 < V4.3.4 |
| Siemens · RUGGEDCOM i801NC | affected 0 < V4.3.4 |
| Siemens · RUGGEDCOM i802 | affected 0 < V4.3.4 |
| Siemens · RUGGEDCOM i802NC | affected 0 < V4.3.4 |
| Siemens · RUGGEDCOM i803 | affected 0 < V4.3.4 |
| Siemens · RUGGEDCOM i803NC | affected 0 < V4.3.4 |
| Siemens · RUGGEDCOM M2100 | affected 0 < V4.3.4 |
| Siemens · RUGGEDCOM M2100NC | affected 0 < V4.3.4 |
| Siemens · RUGGEDCOM M2200 | affected 0 < V4.3.4 |
| Siemens · RUGGEDCOM M2200NC | affected 0 < V4.3.4 |
| Siemens · RUGGEDCOM M969 | affected 0 < V4.3.4 |
| Siemens · RUGGEDCOM M969NC | affected 0 < V4.3.4 |
| Siemens · RUGGEDCOM RMC30 | affected 0 < V4.3.4 |
| Siemens · RUGGEDCOM RMC30NC | affected 0 < V4.3.4 |
| Siemens · RUGGEDCOM RMC8388 V4.X | affected 0 < V4.3.4 |
| Siemens · RUGGEDCOM RMC8388 V5.X | affected 0 < V5.0.1 |
| Siemens · RUGGEDCOM RMC8388NC V4.X | affected 0 < V4.3.4 |
| Siemens · RUGGEDCOM RMC8388NC V5.X | affected 0 < V5.0.1 |
Sources
| Source | Licence |
|---|---|
| CVE List (CVEProject cvelistV5) | CVE Program Terms of Use |
| EPSS (FIRST.org) | FIRST — attribution requested |
| ENISA EUVD | ENISA — reproduction authorised, source acknowledged |
| CERT-FR (ANSSI) | Licence Ouverte / Etalab 2.0 |
| NVD (NIST) via fkie-cad/nvd-json-data-feeds | Public domain — this product uses data from the NVD API but is not endorsed or certified by the NVD |