Siemens CP 1604
At a glance
- Source
- NVD
- EPSS
- EPSS 1.77 % · percentile 78 ()
- State
- PUBLISHED
- Published
- Updated
- Assigner
- siemens
- NVD status
- Modified
Description
A vulnerability has been identified in CP 1604 (All versions), CP 1616 (All versions). An attacker with network access to port 23/tcp could extract internal communication data or cause a Denial-of-Service condition. Successful exploitation requires network access to a vulnerable device. At the time of advisory publication no public exploitation of this vulnerability was known.
Weaknesses (CWE)
- CWE-200 — Exposure of Sensitive Information to an Unauthorized Actor
References
Scores
| Version | Score | Vector | Scored by |
|---|---|---|---|
| CVSS 3.0 | CRITICAL 9.1 | CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H | NVD · nvd@nist.gov (Primary) |
| CVSS 2.0 | MEDIUM 6.4 | AV:N/AC:L/Au:N/C:P/I:N/A:P | NVD · nvd@nist.gov (Primary) |
European references
- ENISA EUVD · EUVD-2018-5744
- GCVE · GCVE-0-2018-13808
CERT-FR advisories
- CERTFR-2019-AVI-004 — SCADA Multiples vulnérabilités dans les produits Siemens · cert.ssi.gouv.fr
Affected configurations (NVD CPE)
cpe:2.3:o:siemens:cp_1604_firmware:*:*:*:*:*:*:*:*≤ 2.8cpe:2.3:o:siemens:cp_1616_firmware:*:*:*:*:*:*:*:*≤ 2.8
Affected products
| Product | Versions |
|---|---|
| Siemens · CP 1604 | affected All versions |
| Siemens · CP 1616 | affected All versions |
Sources
| Source | Licence |
|---|---|
| CVE List (CVEProject cvelistV5) | CVE Program Terms of Use |
| EPSS (FIRST.org) | FIRST — attribution requested |
| ENISA EUVD | ENISA — reproduction authorised, source acknowledged |
| CERT-FR (ANSSI) | Licence Ouverte / Etalab 2.0 |
| NVD (NIST) via fkie-cad/nvd-json-data-feeds | Public domain — this product uses data from the NVD API but is not endorsed or certified by the NVD |