Siemens Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller

CVE-2019-10936
HIGH 7.5

En bref

Source
NVD
EPSS
EPSS 2.07 % · centile 81 ()
État
PUBLISHED
Publiée
Mise à jour
Attribuée par
siemens
Statut NVD
Modified

Description

Affected devices improperly handle large amounts of specially crafted UDP packets. This could allow an unauthenticated remote attacker to trigger a denial of service condition.

Faiblesses (CWE)

  • CWE-400 — Consommation de ressources non maîtrisée (déni de service)

Références

Scores

VersionScoreVecteurÉvalué par
CVSS 3.1HIGH 7.5CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:Csiemens
CVSS 3.1HIGH 7.5CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:HNVD · productcert@siemens.com (Secondary)
CVSS 3.1HIGH 7.5CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:HNVD · nvd@nist.gov (Secondary)
CVSS 2.0MEDIUM 5.0AV:N/AC:L/Au:N/C:N/I:N/A:PNVD · nvd@nist.gov (Primary)

Références européennes

Avis du CERT-FR

Configurations affectées (CPE NVD)

Produits affectés

ProduitVersions
Siemens · Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controlleraffected 0 < *
Siemens · Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200affected 0 < *
Siemens · Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200Paffected All versions < V4.6 Patch 01
Siemens · SIMATIC CFU PAaffected 0 < V1.2.0
Siemens · SIMATIC ET 200AL IM 157-1 PNaffected All versions
Siemens · SIMATIC ET 200M (incl. SIPLUS variants)affected All versions
Siemens · SIMATIC ET 200MP IM 155-5 PN BAaffected 0 < V4.3.0
Siemens · SIMATIC ET 200MP IM 155-5 PN HFaffected 0 < V4.4.0
Siemens · SIMATIC ET 200MP IM 155-5 PN STaffected 0 < *
Siemens · SIMATIC ET 200MP IM 155-5 PN STaffected 0 < *
Siemens · SIMATIC ET 200pro IM 154-3 PN HFaffected 0 < *
Siemens · SIMATIC ET 200pro IM 154-4 PN HFaffected 0 < *
Siemens · SIMATIC ET 200pro IM 154-8 PN/DP CPUaffected All versions < V3.2.17
Siemens · SIMATIC ET 200pro IM 154-8F PN/DP CPUaffected All versions < V3.2.17
Siemens · SIMATIC ET 200pro IM 154-8FX PN/DP CPUaffected All versions < V3.2.17
Siemens · SIMATIC ET 200S IM 151-8 PN/DP CPUaffected All versions < V3.2.17
Siemens · SIMATIC ET 200S IM 151-8F PN/DP CPUaffected All versions < V3.2.17
Siemens · SIMATIC ET 200SP IM 155-6 PN BAaffected 0 < *
Siemens · SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)affected All versions < V1.2.1
Siemens · SIMATIC ET 200SP IM 155-6 PN HFaffected 0 < V4.2.2

Sources

SourceLicence
CVE List (CVEProject cvelistV5)CVE Program Terms of Use
EPSS (FIRST.org)FIRST — attribution requested
ENISA EUVDENISA — reproduction authorised, source acknowledged
CERT-FR (ANSSI)Licence Ouverte / Etalab 2.0
NVD (NIST) via fkie-cad/nvd-json-data-feedsPublic domain — this product uses data from the NVD API but is not endorsed or certified by the NVD