Siemens SCALANCE S602

CVE-2019-13924
MEDIUM 5.4

En bref

Source
NVD
EPSS
EPSS 0.83 % · centile 57 ()
État
PUBLISHED
Publiée
Mise à jour
Attribuée par
siemens
Statut NVD
Modified

Description

A vulnerability has been identified in SCALANCE S602 (All versions < V4.1), SCALANCE S612 (All versions < V4.1), SCALANCE S623 (All versions < V4.1), SCALANCE S627-2M (All versions < V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < 4.1.3). The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website controlled by the attacker. The vulnerability could allow an attacker to perform administrative actions via the web interface.

Faiblesses (CWE)

  • CWE-693 — Défaillance du mécanisme de protection
  • CWE-1021 — Restriction insuffisante des couches d'interface rendues (clickjacking)

Références

Scores

VersionScoreVecteurÉvalué par
CVSS 3.1MEDIUM 5.4CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:NNVD · nvd@nist.gov (Primary)
CVSS 2.0MEDIUM 4.3AV:N/AC:M/Au:N/C:N/I:P/A:NNVD · nvd@nist.gov (Primary)

Références européennes

Avis du CERT-FR

Configurations affectées (CPE NVD)

Produits affectés

ProduitVersions
Siemens · SCALANCE S602affected All versions < V4.1
Siemens · SCALANCE S612affected All versions < V4.1
Siemens · SCALANCE S623affected All versions < V4.1
Siemens · SCALANCE S627-2Maffected All versions < V4.1
Siemens · SCALANCE X-200 switch family (incl. SIPLUS NET variants)affected All versions < 5.2.4
Siemens · SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)affected All versions < V5.5.0
Siemens · SCALANCE X-200RNA switch familyaffected All versions < V3.2.7
Siemens · SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants)affected All versions < 4.1.3

Sources

SourceLicence
CVE List (CVEProject cvelistV5)CVE Program Terms of Use
EPSS (FIRST.org)FIRST — attribution requested
ENISA EUVDENISA — reproduction authorised, source acknowledged
CERT-FR (ANSSI)Licence Ouverte / Etalab 2.0
NVD (NIST) via fkie-cad/nvd-json-data-feedsPublic domain — this product uses data from the NVD API but is not endorsed or certified by the NVD