Siemens AG SIMATIC S7-1200 CPU family (incl. SIPLUS variants)

CVE-2019-13945
MEDIUM 6.8

En bref

Source
NVD
EPSS
EPSS 0.53 % · centile 45 ()
État
PUBLISHED
Publiée
Mise à jour
Attribuée par
siemens
Statut NVD
Modified

Description

A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-1200 CPU family < V4.x (incl. SIPLUS variants) (All versions), SIMATIC S7-1200 CPU family V4.x (incl. SIPLUS variants) (All versions with Function State (FS) < 11), SIMATIC S7-200 SMART CPU CR20s (6ES7 288-1CR20-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR30s (6ES7 288-1CR30-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR40 (6ES7 288-1CR40-0AA0) (All versions <= V2.2.2 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU CR40s (6ES7 288-1CR40-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR60 (6ES7 288-1CR60-0AA0) (All versions <= V2.2.2 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU CR60s (6ES7 288-1CR60-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU SR20 (6ES7 288-1SR20-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 11), SIMATIC S7-200 SMART CPU SR30 (6ES7 288-1SR30-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU SR40 (6ES7 288-1SR40-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU SR60 (6ES7 288-1SR60-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 12), SIMATIC S7-200 SMART CPU ST20 (6ES7 288-1ST20-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 9), SIMATIC S7-200 SMART CPU ST30 (6ES7 288-1ST30-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 9), SIMATIC S7-200 SMART CPU ST40 (6ES7 288-1ST40-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU ST60 (6ES7 288-1ST60-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU family (All versions). There is an access mode used during manufacturing of the affected devices that allows additional diagnostic functionality. The security vulnerability could be exploited by an attacker with physical access to the UART interface during boot process.

Faiblesses (CWE)

  • CWE-749 — Méthode ou fonction dangereuse exposée

Références

Scores

VersionScoreVecteurÉvalué par
CVSS 3.1MEDIUM 6.8CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:HNVD · nvd@nist.gov (Primary)
CVSS 2.0MEDIUM 4.6AV:L/AC:L/Au:N/C:P/I:P/A:PNVD · nvd@nist.gov (Primary)

Références européennes

Avis du CERT-FR

Configurations affectées (CPE NVD)

Produits affectés

ProduitVersions
Siemens AG · SIMATIC S7-1200 CPU family (incl. SIPLUS variants)affected All versions
Siemens AG · SIMATIC S7-1200 CPU family < V4.x (incl. SIPLUS variants)affected All versions
Siemens AG · SIMATIC S7-1200 CPU family V4.x (incl. SIPLUS variants)affected All versions with Function State (FS) < 11
Siemens AG · SIMATIC S7-200 SMART CPU CR20s (6ES7 288-1CR20-0AA1)affected All versions <= V2.3.0 and Function State (FS) <= 3
Siemens AG · SIMATIC S7-200 SMART CPU CR30s (6ES7 288-1CR30-0AA1)affected All versions <= V2.3.0 and Function State (FS) <= 3
Siemens AG · SIMATIC S7-200 SMART CPU CR40 (6ES7 288-1CR40-0AA0)affected All versions <= V2.2.2 and Function State (FS) <= 8
Siemens AG · SIMATIC S7-200 SMART CPU CR40s (6ES7 288-1CR40-0AA1)affected All versions <= V2.3.0 and Function State (FS) <= 3
Siemens AG · SIMATIC S7-200 SMART CPU CR60 (6ES7 288-1CR60-0AA0)affected All versions <= V2.2.2 and Function State (FS) <= 10
Siemens AG · SIMATIC S7-200 SMART CPU CR60s (6ES7 288-1CR60-0AA1)affected All versions <= V2.3.0 and Function State (FS) <= 3
Siemens AG · SIMATIC S7-200 SMART CPU SR20 (6ES7 288-1SR20-0AA0)affected All versions <= V2.5.0 and Function State (FS) <= 11
Siemens AG · SIMATIC S7-200 SMART CPU SR30 (6ES7 288-1SR30-0AA0)affected All versions <= V2.5.0 and Function State (FS) <= 10
Siemens AG · SIMATIC S7-200 SMART CPU SR40 (6ES7 288-1SR40-0AA0)affected All versions <= V2.5.0 and Function State (FS) <= 10
Siemens AG · SIMATIC S7-200 SMART CPU SR60 (6ES7 288-1SR60-0AA0)affected All versions <= V2.5.0 and Function State (FS) <= 12
Siemens AG · SIMATIC S7-200 SMART CPU ST20 (6ES7 288-1ST20-0AA0)affected All versions <= V2.5.0 and Function State (FS) <= 9
Siemens AG · SIMATIC S7-200 SMART CPU ST30 (6ES7 288-1ST30-0AA0)affected All versions <= V2.5.0 and Function State (FS) <= 9
Siemens AG · SIMATIC S7-200 SMART CPU ST40 (6ES7 288-1ST40-0AA0)affected All versions <= V2.5.0 and Function State (FS) <= 8
Siemens AG · SIMATIC S7-200 SMART CPU ST60 (6ES7 288-1ST60-0AA0)affected All versions <= V2.5.0 and Function State (FS) <= 8
Siemens AG · SIMATIC S7-200 SMART CPU familyaffected All versions

Sources

SourceLicence
CVE List (CVEProject cvelistV5)CVE Program Terms of Use
EPSS (FIRST.org)FIRST — attribution requested
ENISA EUVDENISA — reproduction authorised, source acknowledged
CERT-FR (ANSSI)Licence Ouverte / Etalab 2.0
NVD (NIST) via fkie-cad/nvd-json-data-feedsPublic domain — this product uses data from the NVD API but is not endorsed or certified by the NVD