Rockwell Automation ISaGRAF5 Runtime Uncontrolled Search Path Element (Rockwell Automation ISaGRAF Runtime)
En bref
- Source
- NVD
- EPSS
- EPSS 0.45 % · centile 39 ()
- État
- PUBLISHED
- Publiée
- Mise à jour
- Attribuée par
- icscert
- Statut NVD
- Modified
Description
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x searches for and loads DLLs as dynamic libraries. Uncontrolled loading of dynamic libraries could allow a local, unauthenticated attacker to execute arbitrary code. This vulnerability only affects ISaGRAF Runtime when running on Microsoft Windows systems.
Faiblesses (CWE)
- CWE-427 — Élément de chemin de recherche non maîtrisé
Références
- https://www.cisa.gov/uscert/ics/advisories/icsa-20-280-01
- https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1131699
- https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-04
- https://www.xylem.com/siteassets/about-xylem/cybersecurity/advisories/xylem-multismart-rockwell-isagraf.pdf
Scores
| Version | Score | Vecteur | Évalué par |
|---|---|---|---|
| CVSS 3.1 | MEDIUM 6.7 | CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H | icscert |
| CVSS 3.1 | MEDIUM 6.7 | CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H | NVD · ics-cert@hq.dhs.gov (Secondary) |
| CVSS 3.1 | MEDIUM 6.7 | CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H | NVD · nvd@nist.gov (Primary) |
| CVSS 2.0 | MEDIUM 4.6 | AV:L/AC:L/Au:N/C:P/I:P/A:P | NVD · nvd@nist.gov (Primary) |
Références européennes
- ENISA EUVD · EUVD-2020-17873
- GCVE · GCVE-0-2020-25182
Avis du CERT-FR
- CERTFR-2024-AVI-0013 — Multiples vulnérabilités dans les produits Schneider Electric · cert.ssi.gouv.fr
- CERTFR-2021-AVI-443 — Multiples vulnérabilités dans les produits Schneider Electric · cert.ssi.gouv.fr
Configurations affectées (CPE NVD)
cpe:2.3:o:schneider-electric:easergy_t300_firmware:*:*:*:*:*:*:*:*≤ 2.7.1cpe:2.3:o:schneider-electric:easergy_c5_firmware:*:*:*:*:*:*:*:*< 1.1.0cpe:2.3:o:schneider-electric:micom_c264_firmware:*:*:*:*:*:*:*:*< d6.1cpe:2.3:o:schneider-electric:pacis_gtw_firmware:5.1:*:*:*:*:windows:*:*cpe:2.3:o:schneider-electric:pacis_gtw_firmware:5.2:*:*:*:*:windows:*:*cpe:2.3:o:schneider-electric:pacis_gtw_firmware:6.1:*:*:*:*:windows:*:*cpe:2.3:o:schneider-electric:pacis_gtw_firmware:6.3:*:*:*:*:linux:*:*cpe:2.3:o:schneider-electric:pacis_gtw_firmware:6.3:*:*:*:*:windows:*:*cpe:2.3:o:schneider-electric:saitel_dp_firmware:*:*:*:*:*:*:*:*≤ 11.06.21cpe:2.3:o:schneider-electric:epas_gtw_firmware:6.4:*:*:*:*:linux:*:*cpe:2.3:o:schneider-electric:epas_gtw_firmware:6.4:*:*:*:*:windows:*:*cpe:2.3:o:schneider-electric:saitel_dr_firmware:*:*:*:*:*:*:*:*≤ 11.06.12cpe:2.3:o:schneider-electric:scd2200_firmware:*:*:*:*:*:*:*:*≤ 10024cpe:2.3:a:rockwellautomation:aadvance_controller:*:*:*:*:*:*:*:*≤ 1.40cpe:2.3:a:rockwellautomation:isagraf_free_runtime:*:*:*:*:*:isagraf6_workbench:*:*≤ 6.6.8cpe:2.3:o:rockwellautomation:micro810_firmware:-:*:*:*:*:*:*:*cpe:2.3:o:rockwellautomation:micro820_firmware:-:*:*:*:*:*:*:*cpe:2.3:o:rockwellautomation:micro830_firmware:-:*:*:*:*:*:*:*cpe:2.3:o:rockwellautomation:micro850_firmware:-:*:*:*:*:*:*:*cpe:2.3:o:rockwellautomation:micro870_firmware:-:*:*:*:*:*:*:*cpe:2.3:o:xylem:multismart_firmware:*:*:*:*:*:*:*:*< 3.2.0cpe:2.3:a:rockwellautomation:isagraf_runtime:*:*:*:*:*:windows:*:*≥ 5.0 < 6.0
Produits affectés
| Produit | Versions |
|---|---|
| Rockwell Automation · ISaGRAF Runtime | affected 4.x ; affected 5.x |
Sources
| Source | Licence |
|---|---|
| CVE List (CVEProject cvelistV5) | CVE Program Terms of Use |
| EPSS (FIRST.org) | FIRST — attribution requested |
| ENISA EUVD | ENISA — reproduction authorised, source acknowledged |
| CERT-FR (ANSSI) | Licence Ouverte / Etalab 2.0 |
| NVD (NIST) via fkie-cad/nvd-json-data-feeds | Public domain — this product uses data from the NVD API but is not endorsed or certified by the NVD |