Siemens Opcenter Execution Discrete
At a glance
- Source
- NVD
- EPSS
- EPSS 0.38 % · percentile 32 ()
- State
- PUBLISHED
- Published
- Updated
- Assigner
- siemens
- NVD status
- Modified
Description
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). A component within the affected application calls a helper binary with SYSTEM privileges during startup while the call path is not quoted. This could allow a local attacker with administrative privileges to execute code with SYSTEM level privileges.
Weaknesses (CWE)
- CWE-428 — Unquoted Search Path or Element
References
Scores
| Version | Score | Vector | Scored by |
|---|---|---|---|
| CVSS 3.1 | MEDIUM 6.7 | CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H | NVD · nvd@nist.gov (Primary) |
| CVSS 2.0 | HIGH 7.2 | AV:L/AC:L/Au:N/C:C/I:C/A:C | NVD · nvd@nist.gov (Primary) |
European references
- ENISA EUVD · EUVD-2020-28706
- GCVE · GCVE-0-2020-7581
CERT-FR advisories
- CERTFR-2022-AVI-718 — Multiples vulnérabilités dans les produits Siemens · cert.ssi.gouv.fr
- CERTFR-2020-AVI-439 — Multiples vulnérabilités dans les produits Siemens · cert.ssi.gouv.fr
Affected configurations (NVD CPE)
cpe:2.3:a:siemens:opcenter_execution_discrete:*:*:*:*:*:*:*:*< 3.2cpe:2.3:a:siemens:opcenter_execution_foundation:*:*:*:*:*:*:*:*< 3.2cpe:2.3:a:siemens:opcenter_execution_process:*:*:*:*:*:*:*:*< 3.2cpe:2.3:a:siemens:opcenter_intelligence:*:*:*:*:*:*:*:*cpe:2.3:a:siemens:opcenter_quality:*:*:*:*:*:*:*:*< 11.3cpe:2.3:a:siemens:opcenter_rd\&l:8.0:*:*:*:*:*:*:*cpe:2.3:a:siemens:simatic_notifier_server:*:*:*:*:*:windows:*:*cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*< 16cpe:2.3:a:siemens:simatic_step_7:16:-:*:*:*:*:*:*cpe:2.3:a:siemens:simatic_step_7:16:update1:*:*:*:*:*:*cpe:2.3:a:siemens:simocode_es:*:*:*:*:*:*:*:*cpe:2.3:a:siemens:soft_starter_es:*:*:*:*:*:*:*:*
Affected products
| Product | Versions |
|---|---|
| Siemens · Opcenter Execution Discrete | affected All versions < V3.2 |
| Siemens · Opcenter Execution Foundation | affected All versions < V3.2 |
| Siemens · Opcenter Execution Process | affected All versions < V3.2 |
| Siemens · Opcenter Intelligence | affected All versions < V3.3 |
| Siemens · Opcenter Quality | affected All versions < V11.3 |
| Siemens · Opcenter RD&L | affected V8.0 |
| Siemens · SIMATIC Notifier Server for Windows | affected All versions |
| Siemens · SIMATIC PCS neo | affected All versions < V3.0 SP1 |
| Siemens · SIMATIC STEP 7 (TIA Portal) V15 | affected All versions < V15.1 Update 5 |
| Siemens · SIMATIC STEP 7 (TIA Portal) V16 | affected All versions < V16 Update 2 |
| Siemens · SIMOCODE ES V15.1 | affected All versions < V15.1 Update 4 |
| Siemens · SIMOCODE ES V16 | affected All versions < V16 Update 1 |
| Siemens · Soft Starter ES V15.1 | affected All versions < V15.1 Update 3 |
| Siemens · Soft Starter ES V16 | affected All versions < V16 Update 1 |
Sources
| Source | Licence |
|---|---|
| CVE List (CVEProject cvelistV5) | CVE Program Terms of Use |
| EPSS (FIRST.org) | FIRST — attribution requested |
| ENISA EUVD | ENISA — reproduction authorised, source acknowledged |
| CERT-FR (ANSSI) | Licence Ouverte / Etalab 2.0 |
| NVD (NIST) via fkie-cad/nvd-json-data-feeds | Public domain — this product uses data from the NVD API but is not endorsed or certified by the NVD |