Rockwell Automation ISaGRAF Deserialization of Untrusted Data (Rockwell Automation Connected Component Workbench)

CVE-2022-1118
HIGH 8.6

En bref

Source
NVD
EPSS
EPSS 11.10 % · centile 96 ()
État
PUBLISHED
Publiée
Mise à jour
Attribuée par
icscert
Statut NVD
Modified

Description

Connected Components Workbench (v13.00.00 and prior), ISaGRAF Workbench (v6.0 though v6.6.9), and Safety Instrumented System Workstation (v1.2 and prior (for Trusted Controllers)) do not limit the objects that can be deserialized. This allows attackers to craft a malicious serialized object that, if opened by a local user in Connected Components Workbench, may result in arbitrary code execution. This vulnerability requires user interaction to be successfully exploited

Faiblesses (CWE)

  • CWE-502 — Désérialisation de données non fiables

Références

Scores

VersionScoreVecteurÉvalué par
CVSS 3.1HIGH 8.6CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:Hicscert
CVSS 3.1HIGH 8.6CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:HNVD · ics-cert@hq.dhs.gov (Secondary)
CVSS 3.1HIGH 7.8CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:HNVD · nvd@nist.gov (Primary)
CVSS 2.0MEDIUM 6.8AV:N/AC:M/Au:N/C:P/I:P/A:PNVD · nvd@nist.gov (Primary)

Références européennes

Configurations affectées (CPE NVD)

Produits affectés

ProduitVersions
Rockwell Automation · Connected Component Workbenchaffected All ≤ v13.00.00
Rockwell Automation · ISaGRAF Workbenchaffected All v6.0 through v6.6.9
Rockwell Automation · Safety Instrumented Systems Workstationaffected All ≤ v1.2 (for Trusted Controllers)

Sources

SourceLicence
CVE List (CVEProject cvelistV5)CVE Program Terms of Use
EPSS (FIRST.org)FIRST — attribution requested
ENISA EUVDENISA — reproduction authorised, source acknowledged
NVD (NIST) via fkie-cad/nvd-json-data-feedsPublic domain — this product uses data from the NVD API but is not endorsed or certified by the NVD