Siemens SINEMA Remote Connect Server

CVE-2022-27220
MEDIUM 4.3

At a glance

Source
NVD
EPSS
EPSS 0.68 % · percentile 52 ()
State
PUBLISHED
Published
Updated
Assigner
siemens
NVD status
Modified

Description

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0 SP2). Affected application is missing general HTTP security headers in the web server configured on port 6220. This could aid attackers by making the servers more prone to clickjacking, channel downgrade attacks and other similar client-based attack vectors.

Weaknesses (CWE)

  • CWE-358 — Improperly Implemented Security Check for Standard
  • CWE-1021 — Improper Restriction of Rendered UI Layers or Frames

References

Scores

VersionScoreVectorScored by
CVSS 3.1MEDIUM 4.3CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:NNVD · nvd@nist.gov (Primary)
CVSS 2.0MEDIUM 4.3AV:N/AC:M/Au:N/C:N/I:P/A:NNVD · nvd@nist.gov (Primary)

European references

CERT-FR advisories

Affected configurations (NVD CPE)

Affected products

ProductVersions
Siemens · SINEMA Remote Connect Serveraffected All versions < V3.0 SP2

Sources

SourceLicence
CVE List (CVEProject cvelistV5)CVE Program Terms of Use
EPSS (FIRST.org)FIRST — attribution requested
ENISA EUVDENISA — reproduction authorised, source acknowledged
CERT-FR (ANSSI)Licence Ouverte / Etalab 2.0
NVD (NIST) via fkie-cad/nvd-json-data-feedsPublic domain — this product uses data from the NVD API but is not endorsed or certified by the NVD