Description
The OPC UA implementations (ANSI C and C++) in affected products contain an integer overflow vulnerability that could cause the application to run into an infinite loop during certificate validation. This could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate.
Faiblesses (CWE)
- CWE-190 — Débordement d'entier
Références
Scores
| Version | Score | Vecteur | Évalué par |
|---|---|---|---|
| CVSS 3.1 | HIGH 7.5 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H | siemens |
| CVSS 4.0 | HIGH 8.7 | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N | siemens |
| CVSS 4.0 | HIGH 8.7 | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X | NVD · productcert@siemens.com (Secondary) |
| CVSS 3.1 | HIGH 7.5 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H | NVD · productcert@siemens.com (Secondary) |
| CVSS 3.1 | HIGH 7.5 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H | NVD · nvd@nist.gov (Primary) |
Références européennes
- ENISA EUVD · EUVD-2023-32463
- GCVE · GCVE-0-2023-28831
Avis du CERT-FR
- CERTFR-2023-AVI-1015 — Multiples vulnérabilités dans les produits Siemens · cert.ssi.gouv.fr
- CERTFR-2023-AVI-0733 — Multiples vulnérabilités dans les produits Siemens · cert.ssi.gouv.fr
Configurations affectées (CPE NVD)
cpe:2.3:o:siemens:simatic_cloud_connect_7_cc712_firmware:*:*:*:*:*:*:*:*< 2.2cpe:2.3:o:siemens:simatic_cloud_connect_7_cc716_firmware:*:*:*:*:*:*:*:*< 2.2cpe:2.3:o:siemens:simatic_drive_controller_cpu_1504d_tf_firmware:*:*:*:*:*:*:*:*< 2.2cpe:2.3:o:siemens:simatic_drive_controller_cpu_1507d_tf_firmware:*:*:*:*:*:*:*:*< 2.9.7cpe:2.3:o:siemens:simatic_et_200sp_open_controller_cpu_firmware:*:*:*:*:*:*:*:*< 2.9.7cpe:2.3:o:siemens:simatic_s7-1200_cpu_firmware:*:*:*:*:*:*:*:*< 3.0.3cpe:2.3:o:siemens:simatic_s7-1500_cpu_1510sp-1_pn_firmware:*:*:*:*:*:*:*:*< 2.9.7cpe:2.3:o:siemens:simatic_s7-1500_cpu_1510sp_f-1_pn_firmware:*:*:*:*:*:*:*:*< 3.0.3cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511-1_pn_firmware:*:*:*:*:*:*:*:*< 21.9.7cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511c-1_pn_firmware:*:*:*:*:*:*:*:*< 30.0.0cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511f-1_pn_firmware:*:*:*:*:*:*:*:*< 2.9.7cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511t-1_pn_firmware:*:*:*:*:*:*:*:*< 2.9.7cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511tf-1_pn_firmware:*:*:*:*:*:*:*:*< 3.0.3cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512c-1_pn_firmware:*:*:*:*:*:*:*:*< 3.0.3cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512sp-1_pn_firmware:*:*:*:*:*:*:*:*< 2.9.7cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512sp_f-1_pn_firmware:*:*:*:*:*:*:*:*< 3.0.3cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513-1_pn_firmware:*:*:*:*:*:*:*:*< 2.9.7cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513f-1_pn_firmware:*:*:*:*:*:*:*:*< 2.9.7cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513r-1_pn_firmware:*:*:*:*:*:*:*:*< 2.9.7cpe:2.3:o:siemens:simatic_s7-1500_cpu_1514sp-2_pn_firmware:*:*:*:*:*:*:*:*< 3.0.3cpe:2.3:o:siemens:simatic_s7-1500_cpu_1514sp_f-2_pn_firmware:*:*:*:*:*:*:*:*< 2.9.7cpe:2.3:o:siemens:simatic_s7-1500_cpu_1514spt-2_pn_firmware:*:*:*:*:*:*:*:*< 2.9.7cpe:2.3:o:siemens:simatic_s7-1500_cpu_1514spt_f-2_pn_firmware:*:*:*:*:*:*:*:*< 2.9.7cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515-2_pn_firmware:*:*:*:*:*:*:*:*< 2.9.7cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515f-2_pn_firmware:*:*:*:*:*:*:*:*< 3.0.3cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515r-2_pn_firmware:*:*:*:*:*:*:*:*< 2.9.7cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515t-2_pn_firmware:*:*:*:*:*:*:*:*< 3.0.3cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515tf-2_pn_firmware:*:*:*:*:*:*:*:*< 3.0.3cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516-3_pn\/dp_firmware:*:*:*:*:*:*:*:*< 3.0.3cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516f-3_pn\/dp_firmware:*:*:*:*:*:*:*:*< 3.0.3cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516t-3_pn\/dp_firmware:*:*:*:*:*:*:*:*< 3.0.3cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516tf-3_pn\/dp_firmware:*:*:*:*:*:*:*:*< 3.0.3cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517-3_pn\/dp_firmware:*:*:*:*:*:*:*:*< 3.0.3cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517f-3_pn\/dp_firmware:*:*:*:*:*:*:*:*< 2.9.7cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517h-3_pn_firmware:*:*:*:*:*:*:*:*< 2.9.7cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517t-3_pn\/dp_firmware:*:*:*:*:*:*:*:*< 2.9.7cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517tf-3_pn\/dp_firmware:*:*:*:*:*:*:*:*< 2.9.7cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_pn\/dp_firmware:*:*:*:*:*:*:*:*< 21.9.7cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_pn\/dp_mfp_firmware:*:*:*:*:*:*:*:*< 2.9.7cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518f-4_pn\/dp_firmware:*:*:*:*:*:*:*:*< 2.9.7- +39 autres
Produits affectés
Sources
| Source | Licence |
|---|---|
| CVE List (CVEProject cvelistV5) | CVE Program Terms of Use |
| EPSS (FIRST.org) | FIRST — attribution requested |
| ENISA EUVD | ENISA — reproduction authorised, source acknowledged |
| CERT-FR (ANSSI) | Licence Ouverte / Etalab 2.0 |
| NVD (NIST) via fkie-cad/nvd-json-data-feeds | Public domain — this product uses data from the NVD API but is not endorsed or certified by the NVD |