CVE-2023-48363
Siemens OpenPCS 7 V9.1
At a glance
- Source
- NVD
- EPSS
- EPSS 0.27 % · percentile 19 ()
- State
- PUBLISHED
- Published
- Updated
- Assigner
- siemens
- NVD status
- Modified
Description
A vulnerability has been identified in OpenPCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 UC05), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC Route Control V9.1 (All versions < V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions < V8.0 Update 4). The implementation of the RPC (Remote Procedure call) communication protocol in the affected products do not properly handle certain unorganized RPC messages. An attacker could use this vulnerability to cause a denial of service condition in the RPC server.
Weaknesses (CWE)
- CWE-476 — NULL Pointer Dereference
References
Scores
| Version | Score | Vector | Scored by |
|---|---|---|---|
| CVSS 3.1 | MEDIUM 6.5 | CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C | siemens |
| CVSS 4.0 | HIGH 7.1 | CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N | siemens |
| CVSS 4.0 | HIGH 7.1 | CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X | NVD · productcert@siemens.com (Secondary) |
| CVSS 3.1 | MEDIUM 6.5 | CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H | NVD · productcert@siemens.com (Secondary) |
| CVSS 3.1 | MEDIUM 6.5 | CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H | NVD · nvd@nist.gov (Primary) |
European references
- ENISA EUVD · EUVD-2023-52417
- GCVE · GCVE-0-2023-48363
CERT-FR advisories
- CERTFR-2024-AVI-0119 — Multiples vulnérabilités dans les produits Siemens · cert.ssi.gouv.fr
Affected configurations (NVD CPE)
cpe:2.3:a:siemens:openpcs_7:*:*:*:*:*:*:*:*≤ 9.1cpe:2.3:a:siemens:simatic_batch:*:*:*:*:*:*:*:*≤ 9.1cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*≤ 9.1cpe:2.3:a:siemens:simatic_route_control:*:*:*:*:*:*:*:*≤ 9.1cpe:2.3:a:siemens:simatic_wincc:7.4:*:*:*:*:*:*:*cpe:2.3:a:siemens:simatic_wincc:7.5:*:*:*:*:*:*:*cpe:2.3:a:siemens:simatic_wincc:8.0:*:*:*:*:*:*:*cpe:2.3:a:siemens:simatic_wincc_runtime_professional:*:*:*:*:*:*:*:*≤ 18cpe:2.3:a:siemens:simatic_wincc_runtime_professional:19:*:*:*:*:*:*:*
Affected products
| Product | Versions |
|---|---|
| Siemens · OpenPCS 7 V9.1 | affected All versions < V9.1 SP2 UC05 |
| Siemens · SIMATIC BATCH V9.1 | affected All versions < V9.1 SP2 UC05 |
| Siemens · SIMATIC PCS 7 V9.1 | affected 0 < V9.1 SP2 UC05 |
| Siemens · SIMATIC Route Control V9.1 | affected All versions < V9.1 SP2 UC05 |
| Siemens · SIMATIC WinCC Runtime Professional V18 | affected 0 < V18 Update 4 |
| Siemens · SIMATIC WinCC Runtime Professional V19 | affected 0 < V19 Update 2 |
| Siemens · SIMATIC WinCC V7.4 | affected 0 < * |
| Siemens · SIMATIC WinCC V7.5 | affected 0 < V7.5 SP2 Update 15 |
| Siemens · SIMATIC WinCC V8.0 | affected 0 < V8.0 Update 4 |
Sources
| Source | Licence |
|---|---|
| CVE List (CVEProject cvelistV5) | CVE Program Terms of Use |
| EPSS (FIRST.org) | FIRST — attribution requested |
| ENISA EUVD | ENISA — reproduction authorised, source acknowledged |
| CERT-FR (ANSSI) | Licence Ouverte / Etalab 2.0 |
| NVD (NIST) via fkie-cad/nvd-json-data-feeds | Public domain — this product uses data from the NVD API but is not endorsed or certified by the NVD |