Siemens SINEC INS

CVE-2023-48427
HIGH 8.1

En bref

Source
NVD
EPSS
EPSS 0.45 % · centile 39 ()
État
PUBLISHED
Publiée
Mise à jour
Attribuée par
siemens
Statut NVD
Modified

Description

A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 2). Affected products do not properly validate the certificate of the configured UMC server. This could allow an attacker to intercept credentials that are sent to the UMC server as well as to manipulate responses, potentially allowing an attacker to escalate privileges.

Faiblesses (CWE)

  • CWE-295 — Validation incorrecte de certificat

Références

Scores

VersionScoreVecteurÉvalué par
CVSS 3.1HIGH 8.1CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:Csiemens
CVSS 3.1HIGH 8.1CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:HNVD · productcert@siemens.com (Secondary)
CVSS 3.1CRITICAL 9.8CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:HNVD · nvd@nist.gov (Primary)

Références européennes

Avis du CERT-FR

Configurations affectées (CPE NVD)

Produits affectés

ProduitVersions
Siemens · SINEC INSaffected All versions < V1.0 SP2 Update 2

Sources

SourceLicence
CVE List (CVEProject cvelistV5)CVE Program Terms of Use
EPSS (FIRST.org)FIRST — attribution requested
ENISA EUVDENISA — reproduction authorised, source acknowledged
CERT-FR (ANSSI)Licence Ouverte / Etalab 2.0