Siemens SINEC INS

CVE-2023-48428
HIGH 7.2

En bref

Source
NVD
EPSS
EPSS 0.59 % · centile 48 ()
État
PUBLISHED
Publiée
Mise à jour
Attribuée par
siemens
Statut NVD
Modified

Description

A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 2). The radius configuration mechanism of affected products does not correctly check uploaded certificates. A malicious admin could upload a crafted certificate resulting in a denial-of-service condition or potentially issue commands on system level.

Faiblesses (CWE)

  • CWE-78 — Injection de commande système

Références

Scores

VersionScoreVecteurÉvalué par
CVSS 3.1HIGH 7.2CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:Csiemens
CVSS 3.1HIGH 7.2CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:HNVD · productcert@siemens.com (Secondary)

Références européennes

Avis du CERT-FR

Configurations affectées (CPE NVD)

Produits affectés

ProduitVersions
Siemens · SINEC INSaffected All versions < V1.0 SP2 Update 2

Sources

SourceLicence
CVE List (CVEProject cvelistV5)CVE Program Terms of Use
EPSS (FIRST.org)FIRST — attribution requested
ENISA EUVDENISA — reproduction authorised, source acknowledged
CERT-FR (ANSSI)Licence Ouverte / Etalab 2.0
NVD (NIST) via fkie-cad/nvd-json-data-feedsPublic domain — this product uses data from the NVD API but is not endorsed or certified by the NVD