Siemens SINEC INS

CVE-2023-48430
LOW 2.7

At a glance

Source
NVD
EPSS
EPSS 0.58 % · percentile 48 ()
State
PUBLISHED
Published
Updated
Assigner
siemens
NVD status
Modified

Description

A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 2). The REST API of affected devices does not check the length of parameters in certain conditions. This allows a malicious admin to crash the server by sending a crafted request to the API. The server will automatically restart.

Weaknesses (CWE)

  • CWE-392 — Missing Report of Error Condition

References

Scores

VersionScoreVectorScored by
CVSS 3.1LOW 2.7CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:Csiemens
CVSS 3.1LOW 2.7CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:LNVD · productcert@siemens.com (Secondary)
CVSS 3.1LOW 2.7CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:LNVD · nvd@nist.gov (Primary)

European references

CERT-FR advisories

Affected configurations (NVD CPE)

Affected products

ProductVersions
Siemens · SINEC INSaffected All versions < V1.0 SP2 Update 2

Sources

SourceLicence
CVE List (CVEProject cvelistV5)CVE Program Terms of Use
EPSS (FIRST.org)FIRST — attribution requested
ENISA EUVDENISA — reproduction authorised, source acknowledged
CERT-FR (ANSSI)Licence Ouverte / Etalab 2.0
NVD (NIST) via fkie-cad/nvd-json-data-feedsPublic domain — this product uses data from the NVD API but is not endorsed or certified by the NVD