CVE-2023-5517

Querying RFC 1918 reverse zones may cause an assertion failure when "nxdomain-redirect" is enabled

At a glance

Severity
HIGH 7.5
EPSS
EPSS 1.29 % · percentile 70 (2026-10-27)
State
PUBLISHED
Published
Updated
Assigner
isc
NVD status
Modified

Description

A flaw in query-handling code can cause `named` to exit prematurely with an assertion failure when: - `nxdomain-redirect <domain>;` is configured, and - the resolver receives a PTR query for an RFC 1918 address that would normally result in an authoritative NXDOMAIN response. This issue affects BIND 9 versions 9.12.0 through 9.16.45, 9.18.0 through 9.18.21, 9.19.0 through 9.19.19, 9.16.8-S1 through 9.16.45-S1, and 9.18.11-S1 through 9.18.21-S1.

Scores

VersionScoreVectorScored by
CVSS 3.1HIGH 7.5CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:Hisc
CVSS 3.1HIGH 7.5CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:HNVD · security-officer@isc.org (Secondary)

Weaknesses (CWE)

European references

CERT-FR advisories

Affected configurations (NVD CPE)

Affected products

ProductVersions
ISC · BIND 9affected 9.12.0 ≤ 9.16.45 ; affected 9.18.0 ≤ 9.18.21 ; affected 9.19.0 ≤ 9.19.19 ; affected 9.16.8-S1 ≤ 9.16.45-S1 ; affected 9.18.11-S1 ≤ 9.18.21-S1