Schneider Electric PowerLogic HDPM6000
En bref
- Source
- NVD
- EPSS
- EPSS 0.43 % · centile 38 ()
- État
- PUBLISHED
- Publiée
- Mise à jour
- Attribuée par
- schneider
- Statut NVD
- Deferred
Description
CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could allow an unauthorized attacker to modify configuration values outside of the normal range when the attacker sends specific Modbus write packets to the device which could result in invalid data or loss of web interface functionality.
Faiblesses (CWE)
- CWE-119 — Opération hors des limites d'un tampon mémoire
Références
Scores
| Version | Score | Vecteur | Évalué par |
|---|---|---|---|
| CVSS 4.0 | MEDIUM 6.9 | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:L/SC:N/SI:N/SA:N | schneider |
| CVSS 3.1 | MEDIUM 6.5 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L | schneider |
| CVSS 4.0 | MEDIUM 6.9 | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X | NVD · cybersecurity@se.com (Secondary) |
| CVSS 3.1 | MEDIUM 6.5 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L | NVD · cybersecurity@se.com (Secondary) |
Références européennes
- ENISA EUVD · EUVD-2024-33162
- GCVE · GCVE-0-2024-10498
Produits affectés
| Produit | Versions |
|---|---|
| Schneider Electric · PowerLogic HDPM6000 | affected Versions v0.62.7 and prior |
Sources
| Source | Licence |
|---|---|
| CVE List (CVEProject cvelistV5) | CVE Program Terms of Use |
| EPSS (FIRST.org) | FIRST — attribution requested |
| ENISA EUVD | ENISA — reproduction authorised, source acknowledged |
| NVD (NIST) via fkie-cad/nvd-json-data-feeds | Public domain — this product uses data from the NVD API but is not endorsed or certified by the NVD |