Junos OS: EX4300 Series: Loopback filter not blocking traffic despite having discard term. (Juniper Networks Junos)

CVE-2024-30410
MEDIUM 6.9

En bref

Source
NVD
EPSS
EPSS 0.36 % · centile 30 ()
État
PUBLISHED
Publiée
Mise à jour
Attribuée par
juniper
Statut NVD
Analyzed

Description

An Incorrect Behavior Order in the routing engine (RE) of Juniper Networks Junos OS on EX4300 Series allows traffic intended to the device to reach the RE instead of being discarded when the discard term is set in loopback (lo0) interface. The intended function is that the lo0 firewall filter takes precedence over the revenue interface firewall filter.  This issue affects only IPv6 firewall filter. This issue only affects the EX4300 switch. No other products or platforms are affected by this vulnerability.  This issue affects Juniper Networks Junos OS: * All versions before 20.4R3-S10, * from 21.2 before 21.2R3-S7, * from 21.4 before 21.4R3-S6.

Faiblesses (CWE)

  • CWE-696 — Incorrect Behavior Order

Références

Scores

VersionScoreVecteurÉvalué par
CVSS 3.1MEDIUM 5.8CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:Njuniper
CVSS 4.0MEDIUM 6.9CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:N/SC:N/SI:L/SA:Njuniper
CVSS 4.0MEDIUM 6.9CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:N/SC:N/SI:L/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:XNVD · sirt@juniper.net (Secondary)
CVSS 3.1MEDIUM 5.8CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:NNVD · sirt@juniper.net (Secondary)

Références européennes

Avis du CERT-FR

Configurations affectées (CPE NVD)

Produits affectés

ProduitVersions
Juniper Networks · Junosaffected 0 < 20.4R3-S10 ; affected 21.2 < 21.2R3-S7 ; affected 21.4 < 21.4R3-S6

Sources

SourceLicence
CVE List (CVEProject cvelistV5)CVE Program Terms of Use
EPSS (FIRST.org)FIRST — attribution requested
ENISA EUVDENISA — reproduction authorised, source acknowledged
CERT-FR (ANSSI)Licence Ouverte / Etalab 2.0
NVD (NIST) via fkie-cad/nvd-json-data-feedsPublic domain — this product uses data from the NVD API but is not endorsed or certified by the NVD