CVE-2025-40567

En bref

Sévérité
HIGH 7.1
EPSS
EPSS 0.44 % · centile 38 (2026-10-27)
État
PUBLISHED
Publiée
Mise à jour
Attribuée par
siemens
Statut NVD
Deferred

Description

A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions < V3.2), SCALANCE XCH328 (6GK5328-4TS01-2EC2) (All versions < V3.2), SCALANCE XCM324 (6GK5324-8TS01-2AC2) (All versions < V3.2), SCALANCE XCM328 (6GK5328-4TS01-2AC2) (All versions < V3.2), SCALANCE XCM332 (6GK5332-0GA01-2AC2) (All versions < V3.2), SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-4AR3) (All versions < V3.2). The "Load Rollback" functionality in the web interface of affected products contains an incorrect authorization check vulnerability. This could allow an authenticated remote attacker with "guest" role to make the affected product roll back configuration changes made by privileged users.

Scores

VersionScoreVecteurÉvalué par
CVSS 3.1MEDIUM 6.5CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:Nsiemens
CVSS 4.0HIGH 7.1CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:Nsiemens
CVSS 4.0HIGH 7.1CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:XNVD · productcert@siemens.com (Secondary)
CVSS 3.1MEDIUM 6.5CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:NNVD · productcert@siemens.com (Secondary)

Faiblesses (CWE)

Références européennes

Avis du CERT-FR

Produits affectés

ProduitVersions
Siemens · RUGGEDCOM RST2428Paffected 0 < V3.2
Siemens · SCALANCE XCH328affected 0 < V3.2
Siemens · SCALANCE XCM324affected 0 < V3.2
Siemens · SCALANCE XCM328affected 0 < V3.2
Siemens · SCALANCE XCM332affected 0 < V3.2
Siemens · SCALANCE XRH334 (24 V DC, 8xFO, CC)affected 0 < V3.2
Siemens · SCALANCE XRM334 (230 V AC, 12xFO)affected 0 < V3.2
Siemens · SCALANCE XRM334 (230 V AC, 8xFO)affected 0 < V3.2
Siemens · SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+)affected 0 < V3.2
Siemens · SCALANCE XRM334 (24 V DC, 12xFO)affected 0 < V3.2
Siemens · SCALANCE XRM334 (24 V DC, 8xFO)affected 0 < V3.2
Siemens · SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+)affected 0 < V3.2
Siemens · SCALANCE XRM334 (2x230 V AC, 12xFO)affected 0 < V3.2
Siemens · SCALANCE XRM334 (2x230 V AC, 8xFO)affected 0 < V3.2
Siemens · SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+)affected 0 < V3.2

Références

Sources

SourceLicence
CVE List (CVEProject cvelistV5)CVE Program Terms of Use
EPSS (FIRST.org)FIRST — attribution requested
ENISA EUVDENISA — reproduction authorised, source acknowledged
CERT-FR (ANSSI)Licence Ouverte / Etalab 2.0
NVD (NIST) via fkie-cad/nvd-json-data-feedsPublic domain — this product uses data from the NVD API but is not endorsed or certified by the NVD