CVE-2025-40567
En bref
- Sévérité
- HIGH 7.1
- EPSS
- EPSS 0.44 % · centile 38 (2026-10-27)
- État
- PUBLISHED
- Publiée
- Mise à jour
- Attribuée par
- siemens
- Statut NVD
- Deferred
Description
A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions < V3.2), SCALANCE XCH328 (6GK5328-4TS01-2EC2) (All versions < V3.2), SCALANCE XCM324 (6GK5324-8TS01-2AC2) (All versions < V3.2), SCALANCE XCM328 (6GK5328-4TS01-2AC2) (All versions < V3.2), SCALANCE XCM332 (6GK5332-0GA01-2AC2) (All versions < V3.2), SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-4AR3) (All versions < V3.2). The "Load Rollback" functionality in the web interface of affected products contains an incorrect authorization check vulnerability. This could allow an authenticated remote attacker with "guest" role to make the affected product roll back configuration changes made by privileged users.
Scores
| Version | Score | Vecteur | Évalué par |
|---|
| CVSS 3.1 | MEDIUM 6.5 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N | siemens |
| CVSS 4.0 | HIGH 7.1 | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N | siemens |
| CVSS 4.0 | HIGH 7.1 | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X | NVD · productcert@siemens.com (Secondary) |
| CVSS 3.1 | MEDIUM 6.5 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N | NVD · productcert@siemens.com (Secondary) |
Faiblesses (CWE)
Références européennes
Avis du CERT-FR
Produits affectés
| Produit | Versions |
|---|
| Siemens · RUGGEDCOM RST2428P | affected 0 < V3.2 |
| Siemens · SCALANCE XCH328 | affected 0 < V3.2 |
| Siemens · SCALANCE XCM324 | affected 0 < V3.2 |
| Siemens · SCALANCE XCM328 | affected 0 < V3.2 |
| Siemens · SCALANCE XCM332 | affected 0 < V3.2 |
| Siemens · SCALANCE XRH334 (24 V DC, 8xFO, CC) | affected 0 < V3.2 |
| Siemens · SCALANCE XRM334 (230 V AC, 12xFO) | affected 0 < V3.2 |
| Siemens · SCALANCE XRM334 (230 V AC, 8xFO) | affected 0 < V3.2 |
| Siemens · SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) | affected 0 < V3.2 |
| Siemens · SCALANCE XRM334 (24 V DC, 12xFO) | affected 0 < V3.2 |
| Siemens · SCALANCE XRM334 (24 V DC, 8xFO) | affected 0 < V3.2 |
| Siemens · SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) | affected 0 < V3.2 |
| Siemens · SCALANCE XRM334 (2x230 V AC, 12xFO) | affected 0 < V3.2 |
| Siemens · SCALANCE XRM334 (2x230 V AC, 8xFO) | affected 0 < V3.2 |
| Siemens · SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) | affected 0 < V3.2 |
Références
Sources