CVE-2025-40568
Siemens RUGGEDCOM RST2428P
At a glance
- Source
- NVD
- EPSS
- EPSS 0.52 % · percentile 44 ()
- State
- PUBLISHED
- Published
- Updated
- Assigner
- siemens
- NVD status
- Deferred
Description
A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions < V3.2), SCALANCE XCH328 (6GK5328-4TS01-2EC2) (All versions < V3.2), SCALANCE XCM324 (6GK5324-8TS01-2AC2) (All versions < V3.2), SCALANCE XCM328 (6GK5328-4TS01-2AC2) (All versions < V3.2), SCALANCE XCM332 (6GK5332-0GA01-2AC2) (All versions < V3.2), SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-4AR3) (All versions < V3.2). An internal session termination functionality in the web interface of affected products contains an incorrect authorization check vulnerability. This could allow an authenticated remote attacker with "guest" role to terminate legitimate users' sessions.
Weaknesses (CWE)
- CWE-863 — Incorrect Authorization
References
Scores
| Version | Score | Vector | Scored by |
|---|---|---|---|
| CVSS 3.1 | MEDIUM 4.3 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L | siemens |
| CVSS 4.0 | MEDIUM 5.3 | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N | siemens |
| CVSS 4.0 | MEDIUM 5.3 | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X | NVD · productcert@siemens.com (Secondary) |
| CVSS 3.1 | MEDIUM 4.3 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L | NVD · productcert@siemens.com (Secondary) |
European references
- ENISA EUVD · EUVD-2025-17680
- GCVE · GCVE-0-2025-40568
CERT-FR advisories
- CERTFR-2025-AVI-0492 — Multiples vulnérabilités dans les produits Siemens · cert.ssi.gouv.fr
Affected products
| Product | Versions |
|---|---|
| Siemens · RUGGEDCOM RST2428P | affected 0 < V3.2 |
| Siemens · SCALANCE XCH328 | affected 0 < V3.2 |
| Siemens · SCALANCE XCM324 | affected 0 < V3.2 |
| Siemens · SCALANCE XCM328 | affected 0 < V3.2 |
| Siemens · SCALANCE XCM332 | affected 0 < V3.2 |
| Siemens · SCALANCE XRH334 (24 V DC, 8xFO, CC) | affected 0 < V3.2 |
| Siemens · SCALANCE XRM334 (230 V AC, 12xFO) | affected 0 < V3.2 |
| Siemens · SCALANCE XRM334 (230 V AC, 8xFO) | affected 0 < V3.2 |
| Siemens · SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) | affected 0 < V3.2 |
| Siemens · SCALANCE XRM334 (24 V DC, 12xFO) | affected 0 < V3.2 |
| Siemens · SCALANCE XRM334 (24 V DC, 8xFO) | affected 0 < V3.2 |
| Siemens · SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) | affected 0 < V3.2 |
| Siemens · SCALANCE XRM334 (2x230 V AC, 12xFO) | affected 0 < V3.2 |
| Siemens · SCALANCE XRM334 (2x230 V AC, 8xFO) | affected 0 < V3.2 |
| Siemens · SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) | affected 0 < V3.2 |
Sources
| Source | Licence |
|---|---|
| CVE List (CVEProject cvelistV5) | CVE Program Terms of Use |
| EPSS (FIRST.org) | FIRST — attribution requested |
| ENISA EUVD | ENISA — reproduction authorised, source acknowledged |
| CERT-FR (ANSSI) | Licence Ouverte / Etalab 2.0 |
| NVD (NIST) via fkie-cad/nvd-json-data-feeds | Public domain — this product uses data from the NVD API but is not endorsed or certified by the NVD |