CVE-2025-40568

Siemens RUGGEDCOM RST2428P

MEDIUM 5.3

At a glance

Source
NVD
EPSS
EPSS 0.52 % · percentile 44 ()
State
PUBLISHED
Published
Updated
Assigner
siemens
NVD status
Deferred

Description

A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions < V3.2), SCALANCE XCH328 (6GK5328-4TS01-2EC2) (All versions < V3.2), SCALANCE XCM324 (6GK5324-8TS01-2AC2) (All versions < V3.2), SCALANCE XCM328 (6GK5328-4TS01-2AC2) (All versions < V3.2), SCALANCE XCM332 (6GK5332-0GA01-2AC2) (All versions < V3.2), SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-4AR3) (All versions < V3.2). An internal session termination functionality in the web interface of affected products contains an incorrect authorization check vulnerability. This could allow an authenticated remote attacker with "guest" role to terminate legitimate users' sessions.

Weaknesses (CWE)

  • CWE-863 — Incorrect Authorization

References

Scores

VersionScoreVectorScored by
CVSS 3.1MEDIUM 4.3CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:Lsiemens
CVSS 4.0MEDIUM 5.3CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:Nsiemens
CVSS 4.0MEDIUM 5.3CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:XNVD · productcert@siemens.com (Secondary)
CVSS 3.1MEDIUM 4.3CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:LNVD · productcert@siemens.com (Secondary)

European references

CERT-FR advisories

Affected products

ProductVersions
Siemens · RUGGEDCOM RST2428Paffected 0 < V3.2
Siemens · SCALANCE XCH328affected 0 < V3.2
Siemens · SCALANCE XCM324affected 0 < V3.2
Siemens · SCALANCE XCM328affected 0 < V3.2
Siemens · SCALANCE XCM332affected 0 < V3.2
Siemens · SCALANCE XRH334 (24 V DC, 8xFO, CC)affected 0 < V3.2
Siemens · SCALANCE XRM334 (230 V AC, 12xFO)affected 0 < V3.2
Siemens · SCALANCE XRM334 (230 V AC, 8xFO)affected 0 < V3.2
Siemens · SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+)affected 0 < V3.2
Siemens · SCALANCE XRM334 (24 V DC, 12xFO)affected 0 < V3.2
Siemens · SCALANCE XRM334 (24 V DC, 8xFO)affected 0 < V3.2
Siemens · SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+)affected 0 < V3.2
Siemens · SCALANCE XRM334 (2x230 V AC, 12xFO)affected 0 < V3.2
Siemens · SCALANCE XRM334 (2x230 V AC, 8xFO)affected 0 < V3.2
Siemens · SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+)affected 0 < V3.2

Sources

SourceLicence
CVE List (CVEProject cvelistV5)CVE Program Terms of Use
EPSS (FIRST.org)FIRST — attribution requested
ENISA EUVDENISA — reproduction authorised, source acknowledged
CERT-FR (ANSSI)Licence Ouverte / Etalab 2.0
NVD (NIST) via fkie-cad/nvd-json-data-feedsPublic domain — this product uses data from the NVD API but is not endorsed or certified by the NVD