CVE-2025-40569

Siemens RUGGEDCOM RST2428P

MEDIUM 5.9

At a glance

Source
NVD
EPSS
EPSS 0.29 % · percentile 21 ()
State
PUBLISHED
Published
Updated
Assigner
siemens
NVD status
Deferred

Description

A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions < V3.2), SCALANCE XCH328 (6GK5328-4TS01-2EC2) (All versions < V3.2), SCALANCE XCM324 (6GK5324-8TS01-2AC2) (All versions < V3.2), SCALANCE XCM328 (6GK5328-4TS01-2AC2) (All versions < V3.2), SCALANCE XCM332 (6GK5332-0GA01-2AC2) (All versions < V3.2), SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-4AR3) (All versions < V3.2). The "Load Configuration from Local PC" functionality in the web interface of affected products contains a race condition vulnerability. This could allow an authenticated remote attacker to make the affected product load an attacker controlled configuration instead of the legitimate one. Successful exploitation requires that a legitimate administrator invokes the functionality and the attacker wins the race condition.

Weaknesses (CWE)

References

Scores

VersionScoreVectorScored by
CVSS 3.1MEDIUM 4.8CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:N/I:H/A:Nsiemens
CVSS 4.0MEDIUM 5.9CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:P/VC:N/VI:H/VA:N/SC:N/SI:N/SA:Nsiemens
CVSS 4.0MEDIUM 5.9CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:P/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:XNVD · productcert@siemens.com (Secondary)
CVSS 3.1MEDIUM 4.8CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:N/I:H/A:NNVD · productcert@siemens.com (Secondary)

European references

CERT-FR advisories

Affected products

ProductVersions
Siemens · RUGGEDCOM RST2428Paffected 0 < V3.2
Siemens · SCALANCE XCH328affected 0 < V3.2
Siemens · SCALANCE XCM324affected 0 < V3.2
Siemens · SCALANCE XCM328affected 0 < V3.2
Siemens · SCALANCE XCM332affected 0 < V3.2
Siemens · SCALANCE XRH334 (24 V DC, 8xFO, CC)affected 0 < V3.2
Siemens · SCALANCE XRM334 (230 V AC, 12xFO)affected 0 < V3.2
Siemens · SCALANCE XRM334 (230 V AC, 8xFO)affected 0 < V3.2
Siemens · SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+)affected 0 < V3.2
Siemens · SCALANCE XRM334 (24 V DC, 12xFO)affected 0 < V3.2
Siemens · SCALANCE XRM334 (24 V DC, 8xFO)affected 0 < V3.2
Siemens · SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+)affected 0 < V3.2
Siemens · SCALANCE XRM334 (2x230 V AC, 12xFO)affected 0 < V3.2
Siemens · SCALANCE XRM334 (2x230 V AC, 8xFO)affected 0 < V3.2
Siemens · SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+)affected 0 < V3.2

Sources

SourceLicence
CVE List (CVEProject cvelistV5)CVE Program Terms of Use
EPSS (FIRST.org)FIRST — attribution requested
ENISA EUVDENISA — reproduction authorised, source acknowledged
CERT-FR (ANSSI)Licence Ouverte / Etalab 2.0
NVD (NIST) via fkie-cad/nvd-json-data-feedsPublic domain — this product uses data from the NVD API but is not endorsed or certified by the NVD