CVE-2025-40809
At a glance Severity HIGH 7.3 EPSS EPSS 0.14 % · percentile 3 (2026-10-27) State PUBLISHED Published 2025-10-14 Updated 2025-10-14 Assigner siemens NVD status Analyzed
Description A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 14), Solid Edge SE2025 (All versions < V225.0 Update 6). The affected applications contains an out of bounds write vulnerability while parsing specially crafted PRT files. This could allow an attacker to crash the application or execute code in the context of the current process.
Scores Version Score Vector Scored by CVSS 3.1 HIGH 7.8 CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H siemens CVSS 4.0 HIGH 7.3 CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N siemens CVSS 4.0 HIGH 7.3 CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X NVD · productcert@siemens.com (Secondary) CVSS 3.1 HIGH 7.8 CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H NVD · productcert@siemens.com (Secondary)
Weaknesses (CWE)
European references
Affected configurations (NVD CPE) cpe:2.3:a:siemens:solid_edge_se2024:-:*:*:*:*:*:*:*cpe:2.3:a:siemens:solid_edge_se2024:224.0:-:*:*:*:*:*:*cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0001:*:*:*:*:*:*cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_00010:*:*:*:*:*:*cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_00011:*:*:*:*:*:*cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_00012:*:*:*:*:*:*cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_00013:*:*:*:*:*:*cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0002:*:*:*:*:*:*cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0003:*:*:*:*:*:*cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0004:*:*:*:*:*:*cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0005:*:*:*:*:*:*cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0006:*:*:*:*:*:*cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0007:*:*:*:*:*:*cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0008:*:*:*:*:*:*cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0009:*:*:*:*:*:*cpe:2.3:a:siemens:solid_edge_se2025:-:*:*:*:*:*:*:*cpe:2.3:a:siemens:solid_edge_se2025:225.0:-:*:*:*:*:*:*cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0001:*:*:*:*:*:*cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0002:*:*:*:*:*:*cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0003:*:*:*:*:*:*cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0004:*:*:*:*:*:*cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0005:*:*:*:*:*:*
Affected products
References
Sources