Alarm data length not validated against received frame length (RT-Labs P-Net)

CVE-2026-115794
LOW 2.3

At a glance

Source
NVD
State
PUBLISHED
Published
Updated
Assigner
rt-labs
NVD status
Deferred

Description

P-Net before 1.0.3 passes the application alarm callback a data length derived from the variable part length field of a received RTA alarm frame without checking it against the length of the received frame. A short frame can make the callback receive a length of up to 65507 bytes. An application that copies the reported number of bytes reads past the end of the receive buffer. The attacker must have established an Application Relationship and requires ADJACENT network access. Applications that do not use the alarm data are not affected.

Weaknesses (CWE)

  • CWE-130 — Improper Handling of Length Parameter Inconsistency

References

Scores

VersionScoreVectorScored by
CVSS 4.0LOW 2.3CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:L/VI:N/VA:L/SC:N/SI:N/SA:Nrt-labs
CVSS 4.0LOW 2.3CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:L/VI:N/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:XNVD · 4b71179a-3b92-4a9d-b9fc-af8b8ed579ee (Secondary)

European references

Affected products

ProductVersions
RT-Labs · P-Netaffected 0 < 1.0.3

Sources

SourceLicence
CVE List (CVEProject cvelistV5)CVE Program Terms of Use
ENISA EUVDENISA — reproduction authorised, source acknowledged
NVD (NIST) via fkie-cad/nvd-json-data-feedsPublic domain — this product uses data from the NVD API but is not endorsed or certified by the NVD