Cisco RoomOS Logging Subsystem Information Disclosure Vulnerability (Cisco Cisco RoomOS Software)

CVE-2026-20289
MEDIUM 5.7

En bref

Source
NVD
EPSS
EPSS 0.33 % · centile 26 ()
État
PUBLISHED
Publiée
Mise à jour
Attribuée par
cisco
Statut NVD
Analyzed

Description

A vulnerability in the logging subsystem of Cisco RoomOS could allow an authenticated, local attacker with low privileges to access sensitive information. This vulnerability is due to the logging of sensitive information. An attacker could exploit this vulnerability by enabling a specific logging level and then collecting the system logs. A successful exploit could allow the attacker to view sensitive information like user login credentials.

Faiblesses (CWE)

  • CWE-532 — Informations sensibles insérées dans un fichier de journal

Références

Scores

VersionScoreVecteurÉvalué par
CVSS 3.1MEDIUM 5.7CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:Ncisco
CVSS 3.1MEDIUM 5.7CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:NNVD · psirt@cisco.com (Secondary)
CVSS 3.1MEDIUM 6.5CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:NNVD · nvd@nist.gov (Primary)

Références européennes

Configurations affectées (CPE NVD)

Produits affectés

ProduitVersions
Cisco · Cisco RoomOS Softwareaffected RoomOS 10.11.2.2 ; affected RoomOS 10.15.2.2 ; affected RoomOS 11.5.4.6 ; affected RoomOS 11.5.2.4 ; affected RoomOS 10.8.2.5 ; affected RoomOS 10.11.5.2