CVE-2026-26311

Envoy HTTP: filter chain execution on reset streams causing UAF crash

MEDIUM 5.9

At a glance

Source
NVD
EPSS
EPSS 0.36 % · percentile 29 ()
State
PUBLISHED
Published
Updated
Assigner
GitHub_M
NVD status
Analyzed

Description

Envoy is a high-performance edge/middle/service proxy. Prior to 1.37.1, 1.36.5, 1.35.8, and 1.34.13, a logic vulnerability in Envoy's HTTP connection manager (FilterManager) that allows for Zombie Stream Filter Execution. This issue creates a "Use-After-Free" (UAF) or state-corruption window where filter callbacks are invoked on an HTTP stream that has already been logically reset and cleaned up. The vulnerability resides in source/common/http/filter_manager.cc within the FilterManager::decodeData method. The ActiveStream object remains valid in memory during the deferred deletion window. If a DATA frame arrives on this stream immediately after the reset (e.g., in the same packet processing cycle), the HTTP/2 codec invokes ActiveStream::decodeData, which cascades to FilterManager::decodeData. FilterManager::decodeData fails to check the saw_downstream_reset_ flag. It iterates over the decoder_filters_ list and invokes decodeData() on filters that have already received onDestroy(). This vulnerability is fixed in 1.37.1, 1.36.5, 1.35.8, and 1.34.13.

Weaknesses (CWE)

References

Scores

VersionScoreVectorScored by
CVSS 3.1MEDIUM 5.9CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:HGitHub_M
CVSS 3.1MEDIUM 5.9CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:HNVD · security-advisories@github.com (Secondary)

Advisories

European references

Affected configurations (NVD CPE)

Affected products

ProductVersions
envoyproxy · envoyaffected >= 1.37.0, < 1.37.1 ; affected >= 1.36.0, < 1.36.5 ; affected >= 1.35.0, < 1.35.9 ; affected < 1.34.13

Sources

SourceLicence
CVE List (CVEProject cvelistV5)CVE Program Terms of Use
EPSS (FIRST.org)FIRST — attribution requested
ENISA EUVDENISA — reproduction authorised, source acknowledged
NVD (NIST) via fkie-cad/nvd-json-data-feedsPublic domain — this product uses data from the NVD API but is not endorsed or certified by the NVD