Siemens Opcenter Execution Discrete

CVE-2020-7581
MEDIUM 6.7

En bref

Source
NVD
EPSS
EPSS 0.38 % · centile 32 ()
État
PUBLISHED
Publiée
Mise à jour
Attribuée par
siemens
Statut NVD
Modified

Description

A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). A component within the affected application calls a helper binary with SYSTEM privileges during startup while the call path is not quoted. This could allow a local attacker with administrative privileges to execute code with SYSTEM level privileges.

Faiblesses (CWE)

  • CWE-428 — Chemin de recherche non protégé par des guillemets

Références

Scores

VersionScoreVecteurÉvalué par
CVSS 3.1MEDIUM 6.7CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:HNVD · nvd@nist.gov (Primary)
CVSS 2.0HIGH 7.2AV:L/AC:L/Au:N/C:C/I:C/A:CNVD · nvd@nist.gov (Primary)

Références européennes

Avis du CERT-FR

Configurations affectées (CPE NVD)

Produits affectés

ProduitVersions
Siemens · Opcenter Execution Discreteaffected All versions < V3.2
Siemens · Opcenter Execution Foundationaffected All versions < V3.2
Siemens · Opcenter Execution Processaffected All versions < V3.2
Siemens · Opcenter Intelligenceaffected All versions < V3.3
Siemens · Opcenter Qualityaffected All versions < V11.3
Siemens · Opcenter RD&Laffected V8.0
Siemens · SIMATIC Notifier Server for Windowsaffected All versions
Siemens · SIMATIC PCS neoaffected All versions < V3.0 SP1
Siemens · SIMATIC STEP 7 (TIA Portal) V15affected All versions < V15.1 Update 5
Siemens · SIMATIC STEP 7 (TIA Portal) V16affected All versions < V16 Update 2
Siemens · SIMOCODE ES V15.1affected All versions < V15.1 Update 4
Siemens · SIMOCODE ES V16affected All versions < V16 Update 1
Siemens · Soft Starter ES V15.1affected All versions < V15.1 Update 3
Siemens · Soft Starter ES V16affected All versions < V16 Update 1

Sources

SourceLicence
CVE List (CVEProject cvelistV5)CVE Program Terms of Use
EPSS (FIRST.org)FIRST — attribution requested
ENISA EUVDENISA — reproduction authorised, source acknowledged
CERT-FR (ANSSI)Licence Ouverte / Etalab 2.0
NVD (NIST) via fkie-cad/nvd-json-data-feedsPublic domain — this product uses data from the NVD API but is not endorsed or certified by the NVD