CVE-2025-40569
Siemens RUGGEDCOM RST2428P
En bref
- Source
- NVD
- EPSS
- EPSS 0.29 % · centile 21 ()
- État
- PUBLISHED
- Publiée
- Mise à jour
- Attribuée par
- siemens
- Statut NVD
- Deferred
Description
A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions < V3.2), SCALANCE XCH328 (6GK5328-4TS01-2EC2) (All versions < V3.2), SCALANCE XCM324 (6GK5324-8TS01-2AC2) (All versions < V3.2), SCALANCE XCM328 (6GK5328-4TS01-2AC2) (All versions < V3.2), SCALANCE XCM332 (6GK5332-0GA01-2AC2) (All versions < V3.2), SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-4AR3) (All versions < V3.2). The "Load Configuration from Local PC" functionality in the web interface of affected products contains a race condition vulnerability. This could allow an authenticated remote attacker to make the affected product load an attacker controlled configuration instead of the legitimate one. Successful exploitation requires that a legitimate administrator invokes the functionality and the attacker wins the race condition.
Faiblesses (CWE)
- CWE-362 — Situation de compétition
Références
Scores
| Version | Score | Vecteur | Évalué par |
|---|---|---|---|
| CVSS 3.1 | MEDIUM 4.8 | CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:N/I:H/A:N | siemens |
| CVSS 4.0 | MEDIUM 5.9 | CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:P/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N | siemens |
| CVSS 4.0 | MEDIUM 5.9 | CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:P/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X | NVD · productcert@siemens.com (Secondary) |
| CVSS 3.1 | MEDIUM 4.8 | CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:N/I:H/A:N | NVD · productcert@siemens.com (Secondary) |
Références européennes
- ENISA EUVD · EUVD-2025-17679
- GCVE · GCVE-0-2025-40569
Avis du CERT-FR
- CERTFR-2025-AVI-0492 — Multiples vulnérabilités dans les produits Siemens · cert.ssi.gouv.fr
Produits affectés
| Produit | Versions |
|---|---|
| Siemens · RUGGEDCOM RST2428P | affected 0 < V3.2 |
| Siemens · SCALANCE XCH328 | affected 0 < V3.2 |
| Siemens · SCALANCE XCM324 | affected 0 < V3.2 |
| Siemens · SCALANCE XCM328 | affected 0 < V3.2 |
| Siemens · SCALANCE XCM332 | affected 0 < V3.2 |
| Siemens · SCALANCE XRH334 (24 V DC, 8xFO, CC) | affected 0 < V3.2 |
| Siemens · SCALANCE XRM334 (230 V AC, 12xFO) | affected 0 < V3.2 |
| Siemens · SCALANCE XRM334 (230 V AC, 8xFO) | affected 0 < V3.2 |
| Siemens · SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) | affected 0 < V3.2 |
| Siemens · SCALANCE XRM334 (24 V DC, 12xFO) | affected 0 < V3.2 |
| Siemens · SCALANCE XRM334 (24 V DC, 8xFO) | affected 0 < V3.2 |
| Siemens · SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) | affected 0 < V3.2 |
| Siemens · SCALANCE XRM334 (2x230 V AC, 12xFO) | affected 0 < V3.2 |
| Siemens · SCALANCE XRM334 (2x230 V AC, 8xFO) | affected 0 < V3.2 |
| Siemens · SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) | affected 0 < V3.2 |
Sources
| Source | Licence |
|---|---|
| CVE List (CVEProject cvelistV5) | CVE Program Terms of Use |
| EPSS (FIRST.org) | FIRST — attribution requested |
| ENISA EUVD | ENISA — reproduction authorised, source acknowledged |
| CERT-FR (ANSSI) | Licence Ouverte / Etalab 2.0 |
| NVD (NIST) via fkie-cad/nvd-json-data-feeds | Public domain — this product uses data from the NVD API but is not endorsed or certified by the NVD |