CVE-2025-55234
Windows SMB Elevation of Privilege Vulnerability
En bref
- Source
- NVD
- EPSS
- EPSS 20.60 % · centile 98 ()
- État
- PUBLISHED
- Publiée
- Mise à jour
- Attribuée par
- microsoft
- Statut NVD
- Modified
Description
SMB Server might be susceptible to relay attacks depending on the configuration. An attacker who successfully exploited these vulnerabilities could perform relay attacks and make the users subject to elevation of privilege attacks. The SMB Server already supports mechanisms for hardening against relay attacks: SMB Server signing SMB Server Extended Protection for Authentication (EPA) Microsoft is releasing this CVE to provide customers with audit capabilities to help them to assess their environment and to identify any potential device or software incompatibility issues before deploying SMB Server hardening measures that protect against relay attacks. If you have not already enabled SMB Server hardening measures, we advise customers to take the following actions to be protected from these relay attacks: Assess your environment by utilizing the audit capabilities that we are exposing in the September 2025 security updates. See Support for Audit Events to deploy SMB Server Hardening—SMB Server Signing & SMB Server EPA. Adopt appropriate SMB Server hardening measures.
Faiblesses (CWE)
- CWE-287 — Authentification incorrecte
Références
- https://msrc.microsoft.com/update-guide/vulnerability/CVE-2025-55234
- https://www.vicarius.io/vsociety/posts/cve-2025-55234-detection-script-smb-server-vulnerability-affecting-microsoft-systems
- https://www.vicarius.io/vsociety/posts/cve-2025-55234-mitigation-script-smb-server-vulnerability-affecting-microsoft-systems
Scores
| Version | Score | Vecteur | Évalué par |
|---|---|---|---|
| CVSS 3.1 | HIGH 8.8 | CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C | microsoft |
| CVSS 3.1 | HIGH 8.8 | CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H | NVD · secure@microsoft.com (Secondary) |
| CVSS 3.1 | CRITICAL 9.8 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H | NVD · nvd@nist.gov (Primary) |
Références européennes
- ENISA EUVD · EUVD-2025-27294
- GCVE · GCVE-0-2025-55234
Avis du CERT-FR
- CERTFR-2025-AVI-0778 — Multiples vulnérabilités dans Microsoft Windows · cert.ssi.gouv.fr
Configurations affectées (CPE NVD)
cpe:2.3:o:microsoft:windows_10_1507:*:*:*:*:*:*:x64:*< 10.0.10240.21128cpe:2.3:o:microsoft:windows_10_1507:*:*:*:*:*:*:x86:*< 10.0.10240.21128cpe:2.3:o:microsoft:windows_10_1607:*:*:*:*:*:*:x64:*< 10.0.14393.8422cpe:2.3:o:microsoft:windows_10_1607:*:*:*:*:*:*:x86:*< 10.0.14393.8422cpe:2.3:o:microsoft:windows_10_1809:*:*:*:*:*:*:x64:*< 10.0.17763.7792cpe:2.3:o:microsoft:windows_10_1809:*:*:*:*:*:*:x86:*< 10.0.17763.7792cpe:2.3:o:microsoft:windows_10_21h2:*:*:*:*:*:*:*:*< 10.0.19044.6332cpe:2.3:o:microsoft:windows_10_22h2:*:*:*:*:*:*:*:*< 10.0.19045.6332cpe:2.3:o:microsoft:windows_11_22h2:*:*:*:*:*:*:*:*< 10.0.22621.5909cpe:2.3:o:microsoft:windows_11_23h2:*:*:*:*:*:*:*:*< 10.0.22631.5909cpe:2.3:o:microsoft:windows_11_24h2:*:*:*:*:*:*:*:*< 10.0.26100.6508cpe:2.3:o:microsoft:windows_server_2008:-:sp2:*:*:*:*:x64:*cpe:2.3:o:microsoft:windows_server_2008:-:sp2:*:*:*:*:x86:*cpe:2.3:o:microsoft:windows_server_2008:r2:sp1:*:*:*:*:x64:*cpe:2.3:o:microsoft:windows_server_2012:-:*:*:*:*:*:*:*cpe:2.3:o:microsoft:windows_server_2012:r2:*:*:*:*:*:*:*cpe:2.3:o:microsoft:windows_server_2016:*:*:*:*:*:*:*:*< 10.0.14393.8422cpe:2.3:o:microsoft:windows_server_2019:*:*:*:*:*:*:*:*< 10.0.17763.7792cpe:2.3:o:microsoft:windows_server_2022:*:*:*:*:*:*:*:*< 10.0.20348.4106cpe:2.3:o:microsoft:windows_server_2022_23h2:*:*:*:*:*:*:*:*< 10.0.25398.1849cpe:2.3:o:microsoft:windows_server_2025:*:*:*:*:*:*:*:*< 10.0.26100.6508
Produits affectés
Sources
| Source | Licence |
|---|---|
| CVE List (CVEProject cvelistV5) | CVE Program Terms of Use |
| EPSS (FIRST.org) | FIRST — attribution requested |
| ENISA EUVD | ENISA — reproduction authorised, source acknowledged |
| CERT-FR (ANSSI) | Licence Ouverte / Etalab 2.0 |
| NVD (NIST) via fkie-cad/nvd-json-data-feeds | Public domain — this product uses data from the NVD API but is not endorsed or certified by the NVD |